HGB Lyse Reagent Parad HORIBA ABX Hematology Analyzers

HGB Lyse Reagent Parad HORIBA ABX Hematology Analyzers

Say HGB Lyse Reagent parad HORIBA ABX Hematology Analyzers et sakey a cyanmethemoglobin-free chemical solution ya ginawa parad quantitative hemoglobin concentration measurement tan white blood cell differential counting. Say pormulasyon et mamagbag ed saray membrane na erythrocyte, manguuman ed nibulos ya hemoglobin ed sakey a chromophore complex ya walay light absorption peak to ed 540 nm, tan mamasiansia na malinew iran fluidic lines legan na automated optical reading.

Introduksion na produkto

Say HGB Lyse Reagent parad HORIBA ABX Hematology Analyzers et sakey a cyanmethemoglobin-free chemical solution ya ginawa parad quantitative hemoglobin concentration measurement tan white blood cell differential counting. Say pormulasyon et mamagbag ed saray membrane na erythrocyte, manguuman ed nibulos ya hemoglobin ed sakey a chromophore complex ya walay light absorption peak to ed 540 nm, tan mamasiansia na malinew iran fluidic lines legan na automated optical reading.

 

Antoy Hematology Analyzer Lyse Reagent?

 

Say hematology analyzer lyse reagent et sakey ya espisyal a kemikal a solusyon ya walaan na aktibon surfactants ya mapilin mamagbag ed saray membrane na selula ed saray sample na dala. Legan na panagdetermina na hemoglobin, say lysing agent et maneral ed saray red blood cells pian nibulos so membrane-bound hemoglobin, ya magmaliw ya light-absorbing complex parad optical density evaluation ed espisipikon spectrophotometric wavelengths.

 

Aplikasyon ed Hematology Analysis

 

Panukat ed Konsentrasyon na Hemoglobin
Man-lyse na red blood cells pian nibulos so intracellular hemoglobin tan i-convert to itan ed sakey ya stable chromophore complex parad spectrophotometric reading ed 540 nm.
Leukocyte Differential tan Counting
Manpili na white blood cell cytoplasm legan ya pansiasiansiaen so nuclear structures pian nagawaan so volume-based sizing ed saray impedance measurement channels.
Panmintina na Optical Flow Cell
Itutunaw to ray nakekeraan ya selula, ya ag ondarakel so protina tan onlelereg so lipid ed loob na optical cuvettes legan na tuloytuloy ya analytical runs.

 

Compatible Analyzer Series

 

ABX Micros Series

Micros 60, Micros ES 60

ABX Pentra Series

Pentra 60, Pentra 60 C+, Pentra 80, Pentra XL 80

ABX Yumizen Series

Yumizen H500, Yumizen H550

 

Saray Espesipikasyon na Produkto

 

Teknikal a Parametro

Espesipikasyon / Sukat ya Estandarte

Pisikal a Porma

Malinew, andiay kolor, andiay partikulo-ya likido

pH Value (25℃)

7.00 – 7.40

Osmolality

300 – 340 mOsm/kg

Absorbance Blank (540 nm)

Mas abeba odino mipara ed 0.005 AU

Cyanide Content

0.00% (Cyanide-Libren Pormulasyon)

Particulate Background (>2 µm)

Mas abeba odino mipara ed 5 bilang/mL

Correlation Coefficient (R)

Mas baleg nen say 0.99 (No ikompara ed orihinal ya reagent na manggagawa)

Batch-to-Batch Variance

< 1.5% CV

Ag-akalukas ya Bilay na Istante

24 Bulan (Insimpen ed 2℃– 35 degree)

Open-Vial Stability

60 Agew (Diad kontroladon temperatura na kuarto)

 

Saray Manunan Tampok

 

Cyanide-Libren Kemikal ya Pormulasyon
Manggagawa na aliwan-makasamal ya likidon basura, ya mamaandi ed saray espisyal ya kakaukolanen ed panag-neutralize na delikado ya basura parad klinikal ya pangibantak.

0.1 μm Multi-Stage Filtration
Inproseso panamegley na absolute 0.1 μm membrane filters, ya mamantinien so bilang na partikulo ed benegan ya abeba nen 5 counts/mL pian naprotektaan iray micro-fluidic apertures.

Baseline Optical Background Control
Mansiansia na reagent blank absorbance ed o abeba nen 0.005 AU pian naseguro so linear absorbance response ed malaknab iran sukat na hemoglobin.

Electrolyte & Conductivity Alignment
Ipapasen so estandarten fluidic ionic strength pian napansiansia so stable sample flow rates ya ag kaukolan ya i-recalibrate iray system detection factors.

Non-Corrosive Surfactant Blend
Ginawa ya anggapoy agresibon organikon solvent pian ag-onkupas o onkukurang so tapew na acrylic optical flow cells tan translucent tubing.

 

Pakete tan Panangiyan

L ya high-density ya polyethylene (HDPE) ya bote tan 5 L ya HDPE ya lalagan.
Temperatura na Pansimpen:2℃anggad 35℃(36℃F anggad 95℃F).
Proteksion ed Panagpawit:Saray container et walaan na insulated thermal linings pian naprotektaan so inkapekder na produkto sumpad pandurumaan na temperatura legan na kargamento ed dayat tan dagem.
Integridad na Pansara:Walay induction-sealed aluminum foil cap liners pian naprebentaan so evaporation na fluid, ambient oxidation, tan leakage legan na international transit.

 

Panaggawa tan Panangiter

 

ISO Class 7 Cleanroom Production

Inpormula, insala, tan inbotelya ed loob na automated ISO Class 7 cleanrooms pian naprebentaan so kontaminasyon na partikulo tan mikrobyo ed dagem.

Atagey-Purity Water Standard

Manguusar na ultra-puron deionized ya danum ya walay resistivity ya onlampas ed 18.2 MΩ·cm bilang manunan solvent base.

Closed-Loop Processing Telemetry

Manguusar na saray akasara ya panangilaok ya walay inline pH, conductivity, tan viscosity telemetry pian napaaligwas so batch-to-batch consistency.

Saray Protocol ed Pansubok ed Panag-release na Lot

Kada lote na produksyon et ondalan ed spectrophotometric evaluation, background particle counting, tan thermal stress testing antis ya iter so Certificate of Analysis.

 

Saray Mikonektaan ya Reagents ed Dala

 

Hematology Diluent Solution

Isotonic electrolyte solution ya uusaren parad primary blood sample dilution, cell volume stabilization, tan fluidic line flushing.

Enzymatic Cleaner Solution

Proteolytic cleaning solution ya ginawa pian natunaw iray protina ed dala manlapud saray aperture bath tan waste lines.

System Rinse Solution

Surfactant-based rinsing liquid ya uusaren parad automatikon panag-uras na fluidic pathway ed baetan na saray siklo na panagproseso na sample.

 

fAQ

 

T: Kasin sayan lyse reagent et mankaukolan na manual ya sisteman recalibration legan ya i-install?

A: Saray pisikal a parametro na sistema, osmotic pressure, tan absorbance profiles et ginawa pian mipara ed orihinal iran detalye. Saray estandarten kalidad na panangontrol et nirekomenda no manpapasaliw na reagent lots ya ag-umanen so system gain settings.

T: Panon ya say cyanide-free ya pormulasyon et makadampot na inkasusto na panagsukat na photometric?

A: Say surfactant et manguuman ed nibulos ya hemoglobin pian magmaliw ya malet ya imidazole-hemoglobin compound ya mamapawala na absorption spectrum ed 540 nm ya mipara ed tradisyonal iran paraan na cyanmethemoglobin.

T: Anto ran paraan na panag-impake na transportasyon so manproprotekta ed saray kargamento ed saray rota na transportasyon ya atagey so temperatura to?

A: Say kemikal ya pormulasyon et mansiansian malet ed baetan na 2℃tan 35 degree. Saray kargamento ed arum a bansa et manguusar na thermal-insulated container liners tan sealed HDPE packaging pian nabawasan so itatagey na temperatura ed kaliberliber.

T: Anto ran teknikal a kontrol so mangamper ed pakabaraan na fluidic tube tan aperture?

A: Say multi-stage ya panagsalat panamegley na 0.1 μm ya absolute filter membranes et mangekal na micro-particulates, ya mamasiansia ed background particle counts ya walad o abeba nen 5 counts/mL.

T: Anton kalidad na dokumento so kaiba ed kada kargamento?

A: Kada kargamento et walay Lot-Specific Certificate of Analysis (CoA), Material Safety Data Sheet (MSDS), Technical Data Sheet (TDS), tan ISO quality management compliance documentation.

Saray Mainit ya Tag: hgb lyse reagent parad horiba abx hematology analyzers, China hgb lyse reagent parad horiba abx hematology analyzers manufacturers, suppliers